diff options
Diffstat (limited to '1000-hylafaxplus-modem-support.patch')
-rw-r--r-- | 1000-hylafaxplus-modem-support.patch | 135 |
1 files changed, 135 insertions, 0 deletions
diff --git a/1000-hylafaxplus-modem-support.patch b/1000-hylafaxplus-modem-support.patch new file mode 100644 index 000000000000..9b1f888568c8 --- /dev/null +++ b/1000-hylafaxplus-modem-support.patch @@ -0,0 +1,135 @@ +diff -pNaru5 config.Arch/conexant-1.0 config/conexant-1.0 +--- config.Arch/conexant-1.0 2015-07-26 20:46:06.000000000 -0400 ++++ config/conexant-1.0 2019-04-25 00:05:01.600945703 -0400 +@@ -7,13 +7,17 @@ + # support "Class 1.0" which means that they have "adaptive receive" + # (AT+FAR=1), but not V.34. + # + # Comtrol RocketModem II/III/IV + # MultiTech MT5600ZDX ++# MultiTech MT5656ZDX ++# MultiTech MT5600BA + # Zoltrix FMVSP56i3 + # + # CONFIG:CLASS1.0:56000:.*:.*: Manufacturer=Rockwell/Conexant Model=AC/K56 ++# CONFIG:CLASS1.0:MT5600BA-V92:.*:.*: Manufacturer=MultiTech Model=MT5600BA-V92 ++# CONFIG:CLASS1.0:MT5600BA:.*:.*: Manufacturer=MultiTech Model=MT5600BA-V90 + # CONFIG:CLASS1.0:MT5600ZDX:.*:.*: Manufacturer=MultiTech Model=MT5600ZDX + # CONFIG:CLASS1.0:MT5656ZDX*:.*:.*: Manufacturer=MultiTech Model=MT5656ZDX + # CONFIG:CLASS1.0:.*:.*LEONARDO.*:.*: Manufacturer=Digicom Model=Leonardo + # + # BEGIN-SERVER +@@ -36,5 +40,8 @@ ModemHardFlowCmd: AT&K3 # setup hardwar + ModemSoftFlowCmd: AT&K4 # setup software flow control + ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem + ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not) + # + Class1AdaptRecvCmd: AT+FAR=1 # reports carrier detection mismatches ++# ++# ATDT wait for dial tone W produces busy signals on MT5600BA ++#ModemDialCmd: ATDT9,%s +diff -pNaru5 config.Arch/lucent config/lucent +--- config.Arch/lucent 2015-07-26 20:46:06.000000000 -0400 ++++ config/lucent 2019-04-12 14:05:09.188228149 -0400 +@@ -46,10 +46,12 @@ + # CONFIG:CLASS1:Zoom V.90 Serial*:.*:.*: Manufacturer=Zoom Model=2949L + # CONFIG:CLASS1:EFM560 VER*:.*:.*: Manufacturer=AboCom Model=EFM560 + # CONFIG:CLASS1:Mainpine Venus V.92*:.*:.*: Manufacturer=Mainpine Model=RockForce + # CONFIG:CLASS1:Mainpine CFAX34*:.*:.*: Manufacturer=Mainpine Model='IQ Express' + # CONFIG:CLASS1:.*:Mainpine CFAX34*:.*: Manufacturer=Mainpine Model='IQ Express' ++# CONFIG:CLASS1:LT 33.6 MT3334ZDX*:.*:.*: Manufacturer=Lucent Model='MT3334ZDX' ++# CONFIG:CLASS1:Agere OCM V.92 MT9234ZBA*:.*:.*: Manufacturer=MultiTech Model=MT9234ZBA + # CONFIG:CLASS1:Agere OCM V.92*:.*:.*: Manufacturer=Agere Model=OCM + # CONFIG:CLASS1:AGERE OCM V.92*:.*:.*: Manufacturer=Agere Model=OCM + # + # BEGIN-SERVER + # END-SERVER +diff -pNaru5 config.Arch/lucent-mt-10 config/lucent-mt-10 +--- config.Arch/lucent-mt-10 2015-07-26 20:46:06.000000000 -0400 ++++ config/lucent-mt-10 2019-04-12 14:05:09.188228149 -0400 +@@ -10,10 +10,11 @@ + # CONFIG:CLASS1.0:LT V.90 1.0 MT5634ZBA*:.*:.*: Manufacturer=MultiTech Model=MT5634ZBA + # CONFIG:CLASS1.0:LT V.92 1.0 MT5634ZBA*:.*:.*: Manufacturer=MultiTech Model=MT5634ZBA + # CONFIG:CLASS1.0:LT V.90 1.0 ISI5634PCI*:.*:.*: Manufacturer=MultiTech Model=ISI5634PCI + # CONFIG:CLASS1.0:LT V.92 1.0 ISI5634PCI*:.*:.*: Manufacturer=MultiTech Model=ISI5634PCI + # CONFIG:CLASS1.0:LT V.92 1.0 MT5634SMI*:.*:.*: Manufacturer=MultiTech Model=MT5634SMI ++# CONFIG:CLASS1.0:Agere OCM V.92 MT9234ZBA*:.*:.*: Manufacturer=MultiTech Model=MT9234ZBA + # CONFIG:CLASS1.0:Agere OCM V.92*:.*:.*: Manufacturer=Agere Model=OCM + # CONFIG:CLASS1.0:AGERE OCM V.92*:.*:.*: Manufacturer=Agere Model=OCM + # + # BEGIN-SERVER + # END-SERVER +diff -pNaru5 config.Arch/lucent-mt-2 config/lucent-mt-2 +--- config.Arch/lucent-mt-2 2015-07-26 20:46:06.000000000 -0400 ++++ config/lucent-mt-2 2019-04-12 14:05:09.188228149 -0400 +@@ -9,10 +9,11 @@ + # + + # + # CONFIG: CLASS2:"Multi-Tech Systems"-"MT5634ZPX-PCI"-* + # CONFIG: CLASS2:"Multi-Tech Systems"-"MT5634ZBA"-* ++# CONFIG: CLASS2:"Multi-Tech Systems"-*"MT3334ZDX"* + # CONFIG: CLASS2:*-"ISI5634PCI"-* + # CONFIG: CLASS2:*-"MT5634SMI-V92"-* + # + # BEGIN-SERVER + # END-SERVER +diff -pNaru5 config.Arch/rc288dpi-1 config/rc288dpi-1 +--- config.Arch/rc288dpi-1 2015-07-26 20:46:06.000000000 -0400 ++++ config/rc288dpi-1 2019-04-12 14:06:52.938859444 -0400 +@@ -38,10 +38,12 @@ + # switches to XON/XOFF (testing host was too fast to see). + # + # CONFIG:CLASS1:28800:.*:.*: Manufacturer=ROCKWELL Model=RC288DPi + # CONFIG:CLASS1:33600:.*:.*: Manufacturer=Rockwell Model=33600 + # CONFIG:CLASS1:56000:.*:.*: Manufacturer=Rockwell/Conexant Model=AC/K56 ++# CONFIG:CLASS1:MT5600BA-V92:.*:.*: Manufacturer=MultiTech Model=MT5600BA-V92 ++# CONFIG:CLASS1:MT5600BA:.*:.*: Manufacturer=MultiTech Model=MT5600BA + # CONFIG:CLASS1:MT5600ZDX:.*:.*: Manufacturer=MultiTech Model=MT5600ZDX + # CONFIG:CLASS1:MT5656ZDX*:.*:.*: Manufacturer=MultiTech Model=MT5656ZDX + # + # BEGIN-SERVER + # END-SERVER +diff -pNaru5 config.Arch/usr-rts config/usr-rts +--- config.Arch/usr-rts 2015-07-26 20:46:06.000000000 -0400 ++++ config/usr-rts 2019-04-24 23:18:18.003137846 -0400 +@@ -79,13 +79,18 @@ ModemSetupAACmd: AT+FCLASS=0 # leave mod + ModemAnswerCmd: AT+FCLASS=1 # force RTS/CTS after change + # + # Disables the reporting of bad frames by the modem. This + # overcomes a firmware problem in the x2 and V90 Sportsters. + # It is not necessary for the Courier modem. ++# It errors on the Sportster 5686G V.92. + # +-Class2NRCmd: AT+FNR=1,1,1,0 ++#Class2NRCmd: AT+FNR=1,1,1,0 + # ++# Sportster 5686G (Agere CV92) doesn't respond correctly to AT+FTM=? ++#Class1TMQueryCmd: "!3,24,48,72,73,74,96,97,98,121,122,145,146" ++#Class1RMQueryCmd: "!3,24,48,72,73,74,96,97,98,121,122,145,146" ++# + # When using AT+FRS=n we see USR modems reset themselves in the middle of sessions + # this is not good. So, we seem to work-around that problem by not using the + # command. Unfortunately, this isn't an ideal thing. + # + Class1SwitchingCmd: "<delay\0727>" +diff -pNaru5 config.Arch/zyxel-1496e-1 config/zyxel-1496e-1 +--- config.Arch/zyxel-1496e-1 2015-07-26 20:46:06.000000000 -0400 ++++ config/zyxel-1496e-1 2019-04-24 23:28:05.746941599 -0400 +@@ -60,14 +60,14 @@ ModemSetupAACmd: AT+FAA=1 # enable in cu + # Additional reset commands: + # + # &B1 DTE-DCE rate is fixed at DTE setting + # &N0 Auto-negotiate highest possible DCE-DCE link rate + # &S0 DSR always on +-# *F0 Deny remote configuration ++# *F0 Deny remote configuration (removed due to error on U90E) + # S38.3=1 DCD on/off sequence follows UNIX standard + # +-ModemResetCmds: AT&B1&N0&S0*F0S38.3=1 ++ModemResetCmds: AT&B1&N0&S0S38.3=1 + # + # We normally append the "@" symbol to the dial string so that + # the modem will wait 5 seconds before attempting to connect + # and return result codes that distinguish between no carrier + # and no answer. This makes it possible to avoid problems with |