summarylogtreecommitdiffstats
path: root/1000-hylafaxplus-modem-support.patch
diff options
context:
space:
mode:
Diffstat (limited to '1000-hylafaxplus-modem-support.patch')
-rw-r--r--1000-hylafaxplus-modem-support.patch135
1 files changed, 135 insertions, 0 deletions
diff --git a/1000-hylafaxplus-modem-support.patch b/1000-hylafaxplus-modem-support.patch
new file mode 100644
index 000000000000..9b1f888568c8
--- /dev/null
+++ b/1000-hylafaxplus-modem-support.patch
@@ -0,0 +1,135 @@
+diff -pNaru5 config.Arch/conexant-1.0 config/conexant-1.0
+--- config.Arch/conexant-1.0 2015-07-26 20:46:06.000000000 -0400
++++ config/conexant-1.0 2019-04-25 00:05:01.600945703 -0400
+@@ -7,13 +7,17 @@
+ # support "Class 1.0" which means that they have "adaptive receive"
+ # (AT+FAR=1), but not V.34.
+ #
+ # Comtrol RocketModem II/III/IV
+ # MultiTech MT5600ZDX
++# MultiTech MT5656ZDX
++# MultiTech MT5600BA
+ # Zoltrix FMVSP56i3
+ #
+ # CONFIG:CLASS1.0:56000:.*:.*: Manufacturer=Rockwell/Conexant Model=AC/K56
++# CONFIG:CLASS1.0:MT5600BA-V92:.*:.*: Manufacturer=MultiTech Model=MT5600BA-V92
++# CONFIG:CLASS1.0:MT5600BA:.*:.*: Manufacturer=MultiTech Model=MT5600BA-V90
+ # CONFIG:CLASS1.0:MT5600ZDX:.*:.*: Manufacturer=MultiTech Model=MT5600ZDX
+ # CONFIG:CLASS1.0:MT5656ZDX*:.*:.*: Manufacturer=MultiTech Model=MT5656ZDX
+ # CONFIG:CLASS1.0:.*:.*LEONARDO.*:.*: Manufacturer=Digicom Model=Leonardo
+ #
+ # BEGIN-SERVER
+@@ -36,5 +40,8 @@ ModemHardFlowCmd: AT&K3 # setup hardwar
+ ModemSoftFlowCmd: AT&K4 # setup software flow control
+ ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
+ ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
+ #
+ Class1AdaptRecvCmd: AT+FAR=1 # reports carrier detection mismatches
++#
++# ATDT wait for dial tone W produces busy signals on MT5600BA
++#ModemDialCmd: ATDT9,%s
+diff -pNaru5 config.Arch/lucent config/lucent
+--- config.Arch/lucent 2015-07-26 20:46:06.000000000 -0400
++++ config/lucent 2019-04-12 14:05:09.188228149 -0400
+@@ -46,10 +46,12 @@
+ # CONFIG:CLASS1:Zoom V.90 Serial*:.*:.*: Manufacturer=Zoom Model=2949L
+ # CONFIG:CLASS1:EFM560 VER*:.*:.*: Manufacturer=AboCom Model=EFM560
+ # CONFIG:CLASS1:Mainpine Venus V.92*:.*:.*: Manufacturer=Mainpine Model=RockForce
+ # CONFIG:CLASS1:Mainpine CFAX34*:.*:.*: Manufacturer=Mainpine Model='IQ Express'
+ # CONFIG:CLASS1:.*:Mainpine CFAX34*:.*: Manufacturer=Mainpine Model='IQ Express'
++# CONFIG:CLASS1:LT 33.6 MT3334ZDX*:.*:.*: Manufacturer=Lucent Model='MT3334ZDX'
++# CONFIG:CLASS1:Agere OCM V.92 MT9234ZBA*:.*:.*: Manufacturer=MultiTech Model=MT9234ZBA
+ # CONFIG:CLASS1:Agere OCM V.92*:.*:.*: Manufacturer=Agere Model=OCM
+ # CONFIG:CLASS1:AGERE OCM V.92*:.*:.*: Manufacturer=Agere Model=OCM
+ #
+ # BEGIN-SERVER
+ # END-SERVER
+diff -pNaru5 config.Arch/lucent-mt-10 config/lucent-mt-10
+--- config.Arch/lucent-mt-10 2015-07-26 20:46:06.000000000 -0400
++++ config/lucent-mt-10 2019-04-12 14:05:09.188228149 -0400
+@@ -10,10 +10,11 @@
+ # CONFIG:CLASS1.0:LT V.90 1.0 MT5634ZBA*:.*:.*: Manufacturer=MultiTech Model=MT5634ZBA
+ # CONFIG:CLASS1.0:LT V.92 1.0 MT5634ZBA*:.*:.*: Manufacturer=MultiTech Model=MT5634ZBA
+ # CONFIG:CLASS1.0:LT V.90 1.0 ISI5634PCI*:.*:.*: Manufacturer=MultiTech Model=ISI5634PCI
+ # CONFIG:CLASS1.0:LT V.92 1.0 ISI5634PCI*:.*:.*: Manufacturer=MultiTech Model=ISI5634PCI
+ # CONFIG:CLASS1.0:LT V.92 1.0 MT5634SMI*:.*:.*: Manufacturer=MultiTech Model=MT5634SMI
++# CONFIG:CLASS1.0:Agere OCM V.92 MT9234ZBA*:.*:.*: Manufacturer=MultiTech Model=MT9234ZBA
+ # CONFIG:CLASS1.0:Agere OCM V.92*:.*:.*: Manufacturer=Agere Model=OCM
+ # CONFIG:CLASS1.0:AGERE OCM V.92*:.*:.*: Manufacturer=Agere Model=OCM
+ #
+ # BEGIN-SERVER
+ # END-SERVER
+diff -pNaru5 config.Arch/lucent-mt-2 config/lucent-mt-2
+--- config.Arch/lucent-mt-2 2015-07-26 20:46:06.000000000 -0400
++++ config/lucent-mt-2 2019-04-12 14:05:09.188228149 -0400
+@@ -9,10 +9,11 @@
+ #
+
+ #
+ # CONFIG: CLASS2:"Multi-Tech Systems"-"MT5634ZPX-PCI"-*
+ # CONFIG: CLASS2:"Multi-Tech Systems"-"MT5634ZBA"-*
++# CONFIG: CLASS2:"Multi-Tech Systems"-*"MT3334ZDX"*
+ # CONFIG: CLASS2:*-"ISI5634PCI"-*
+ # CONFIG: CLASS2:*-"MT5634SMI-V92"-*
+ #
+ # BEGIN-SERVER
+ # END-SERVER
+diff -pNaru5 config.Arch/rc288dpi-1 config/rc288dpi-1
+--- config.Arch/rc288dpi-1 2015-07-26 20:46:06.000000000 -0400
++++ config/rc288dpi-1 2019-04-12 14:06:52.938859444 -0400
+@@ -38,10 +38,12 @@
+ # switches to XON/XOFF (testing host was too fast to see).
+ #
+ # CONFIG:CLASS1:28800:.*:.*: Manufacturer=ROCKWELL Model=RC288DPi
+ # CONFIG:CLASS1:33600:.*:.*: Manufacturer=Rockwell Model=33600
+ # CONFIG:CLASS1:56000:.*:.*: Manufacturer=Rockwell/Conexant Model=AC/K56
++# CONFIG:CLASS1:MT5600BA-V92:.*:.*: Manufacturer=MultiTech Model=MT5600BA-V92
++# CONFIG:CLASS1:MT5600BA:.*:.*: Manufacturer=MultiTech Model=MT5600BA
+ # CONFIG:CLASS1:MT5600ZDX:.*:.*: Manufacturer=MultiTech Model=MT5600ZDX
+ # CONFIG:CLASS1:MT5656ZDX*:.*:.*: Manufacturer=MultiTech Model=MT5656ZDX
+ #
+ # BEGIN-SERVER
+ # END-SERVER
+diff -pNaru5 config.Arch/usr-rts config/usr-rts
+--- config.Arch/usr-rts 2015-07-26 20:46:06.000000000 -0400
++++ config/usr-rts 2019-04-24 23:18:18.003137846 -0400
+@@ -79,13 +79,18 @@ ModemSetupAACmd: AT+FCLASS=0 # leave mod
+ ModemAnswerCmd: AT+FCLASS=1 # force RTS/CTS after change
+ #
+ # Disables the reporting of bad frames by the modem. This
+ # overcomes a firmware problem in the x2 and V90 Sportsters.
+ # It is not necessary for the Courier modem.
++# It errors on the Sportster 5686G V.92.
+ #
+-Class2NRCmd: AT+FNR=1,1,1,0
++#Class2NRCmd: AT+FNR=1,1,1,0
+ #
++# Sportster 5686G (Agere CV92) doesn't respond correctly to AT+FTM=?
++#Class1TMQueryCmd: "!3,24,48,72,73,74,96,97,98,121,122,145,146"
++#Class1RMQueryCmd: "!3,24,48,72,73,74,96,97,98,121,122,145,146"
++#
+ # When using AT+FRS=n we see USR modems reset themselves in the middle of sessions
+ # this is not good. So, we seem to work-around that problem by not using the
+ # command. Unfortunately, this isn't an ideal thing.
+ #
+ Class1SwitchingCmd: "<delay\0727>"
+diff -pNaru5 config.Arch/zyxel-1496e-1 config/zyxel-1496e-1
+--- config.Arch/zyxel-1496e-1 2015-07-26 20:46:06.000000000 -0400
++++ config/zyxel-1496e-1 2019-04-24 23:28:05.746941599 -0400
+@@ -60,14 +60,14 @@ ModemSetupAACmd: AT+FAA=1 # enable in cu
+ # Additional reset commands:
+ #
+ # &B1 DTE-DCE rate is fixed at DTE setting
+ # &N0 Auto-negotiate highest possible DCE-DCE link rate
+ # &S0 DSR always on
+-# *F0 Deny remote configuration
++# *F0 Deny remote configuration (removed due to error on U90E)
+ # S38.3=1 DCD on/off sequence follows UNIX standard
+ #
+-ModemResetCmds: AT&B1&N0&S0*F0S38.3=1
++ModemResetCmds: AT&B1&N0&S0S38.3=1
+ #
+ # We normally append the "@" symbol to the dial string so that
+ # the modem will wait 5 seconds before attempting to connect
+ # and return result codes that distinguish between no carrier
+ # and no answer. This makes it possible to avoid problems with